Independently certified by Underwriters Laboratories to UL857, the DATABAR busbar system is the safest and most innovative solution on the market today.
DATABAR boasts two patented design elements that deliver a unique, compact and safe open channel system, specifically designed for critical rack power distribution.
The DATABAR busbar can be installed above the rack or under a raised floor, in a horizontal or a vertical orientation, all contributing to flexibility when space is limited. Tap-off units can be installed at any position along the busway and over the joint area if required and, when the tap-off is installed on the busbar, DATABAR delivers the smallest clearance level in the market.
The unique tap-off design also provides the essential safety element when inserting a tap-off onto a live busway system. The power contacts are engaged via a patented actuation system which not only controls the tap-off contacts, but also interlocks with the switching device to ensure that no load is connected during the engage operation.
All in all, DATABAR delivers engineering excellence, innovation and the safest solution available.






| SPECIFICATIONS | SYSTEM RATINGS | |||||
| System ampacity | A | 160 | 250 | 400 | 600 | 800 |
| Operating voltage | V | Up to 600V | ||||
| Frequency | Hz | 50/60 Hz | ||||
| Degree of protection | Finger Safe (IP2X) | |||||
| Casing material | Aluminium | |||||
| Conductor material | Copper | |||||
| Conductor finish | Plain (Plated Opt.) | Plated | ||||
| Short Circuit Current Rating (unprotected) | 42kAIC up to 208VAC* | 50kAIC up to 600VAC** | ||||
| 35kAIC up to 600VAC | 35kAIC up to 600VAC | |||||
Case refers to aluminium casing used as ground. Isolated refers to internal insulated pole for ground. *Option to upgrade to 42kA, standard rating is 35kA. **Option to upgrade to 50kA, standard rating is 35kA.
| Dimensions | 160 | 250 | 400 | 600 | 800 | |
| Case overall dimensions (4P & 5P) | in | 6.5 x 1.9 | 6.5 x 1.9 | 6.5 x 1.9 | 6.5 x 3.5 | 6.5 x 3.5 |
| mm | 165 x 47 | 165 x 47 | 165 x 47 | 165 x 90 | 165 x 90 | |
| Phase Conductor CSA | in² | 0.3 | 0.3 | 0.3 | 0.8 | 0.8 |
| mm² | 194 | 194 | 194 | 514 | 514 | |
| Neutral Conductor CSA | in² | 0.3 | 0.3 | 0.3 | 0.8 | 0.8 |
| mm² | 194 | 194 | 194 | 514 | 514 | |
| Isolated Ground Conductor CSA | in² | 0.3 | 0.3 | 0.3 | 0.8 | 0.8 |
| mm² | 194 | 194 | 194 | 514 | 514 | |
| Housing CSA (Ground) | in² | 2.26 | 2.26 | 2.26 | 4.94 | 4.94 |
| mm² | 1457 | 1457 | 1457 | 3189 | 3189 | |
| System Weight (4 pole) | lbs/ft | 8.7 | 8.7 | 8.7 | 19.6 | 19.6 |
| kg/m | 12.9 | 12.9 | 12.9 | 29.1 | 29.1 | |
| System Weight (5 Pole) | lbs/ft | 9.7 | 9.7 | 9.7 | 22.9 | 22.9 |
| kg/m | 14.5 | 14.5 | 14.5 | 34.1 | 34.1 | |